Diagnosis Procedure
1. Perform initialization procedure
Perform initialization procedure.
Refer to rf-18, "additional service when replacing control unit : special repair requirement".
Is the inspection result normal? Yes >> inspection end.
No >> perform basic inspection. Refer to rf-16, "work flow".
Auto operation does not operate
Does not stop fully-open or fullyclosed
positionAmbient sensor signal circuit
Description
It detects outside air temperature and converts it into a resistance value
which is then input into the combination
meter.
Diagnosis Procedure
Regarding wiring diagram information, refer to mwi-28, "wiring diagram".
1.Check ambient sensor signal circuit
Turn igniti ...
The oil pressure warning lamp does not turn on
Description
The oil pressure warning lamp stays off when the ignition switch is turned
on.
Diagnosis procedure
1.Check combination meter oil pressure warning light
Select METER/M&A on CONSULT.
Observe oil w/l data monitor while operating the ignition switch.
Is the inspection r ...
Rear power window switch
Removal and Installation
REMOVAL
Release the pawls using a suitable tool and lift the rear power window
switch and finisher as an assembly
and remove
Disconnect the harness connector from the rear power window switch.
Release the pawl (one on each side) using a suitable tool, then
se ...