Diagnosis procedure
1.Check connector
Is the inspection result normal? Yes >> go to 2.
No >> repair the terminal and connector.
2.Check harness for open circuit

Is the measurement value within the specification? YES >> GO TO 3.
NO >> Repair the combination meter branch line.
3.Check power supply and ground circuit
Check the power supply and the ground circuit of the combination meter. Refer to mwi-52, "combination meter : diagnosis procedure".
Is the inspection result normal? Yes (present error)>>replace the combination meter. Refer to mwi-77, "removal and installation".
Yes (past error)>>error was detected in the combination meter branch line.
No >> repair the power supply and the ground circuit.
Eps branch line circuit
Strg branch line circuitExterior rear
Trunk lid
High mount stop light
Replacing bulbs
Rear window defroster switch
Child safety rear door lock
Fuel-filler door , Fuel-filler cap,fuel recommendation
Rearview camera (if so equipped)
Exterior trunk lid release, Interior trunk lid release (if so equipped)
See the pag ...
P0456 EVAP Control system
DTC Logic
DTC DETECTION LOGIC
This diagnosis detects leaks in the EVAP line between fuel tank and EVAP
canister purge volume control solenoid
valve, using the negative pressure caused by decrease of fuel temperature in the
fuel tank after turning
ignition switch OFF.
If ECM judges there a ...