Description
When the power window main switch is replaced, the initialization is necessary for normal operation of power window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
Work Procedure
1.SYSTEM INITIALIZATION
Perform system initialization. Refer to PWC-29, "Work Procedure".
>> GO TO 2.
2.CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to PWC-30, "Work Procedure".
>> END
Additional service when removing battery negative terminal
System initializationDTC/Circuit diagnosis
POSITION SWITCH
BACK-UP LAMP SWITCH
BACK-UP LAMP SWITCH : Component Inspection
1.CHECK BACK-UP LAMP SWITCH
Disconnect position switch harness connector. Refer to TM-21, "Removal
and Installation".
Check continuity between position switch terminals.
Is the inspection ...
M&a branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the combination meter for damage,
bend and loose connection
(unit side and connector side).
Is the inspection result nor ...
Operating tips
CAUTION
Do not use alcohol, benzine or thinner
to clean the camera. This will cause
discoloration. To clean the camera,
wipe with a cloth dampened with a diluted
mild cleaning agent and then wipe
with a dry cloth.
Do not damage the camera as the monitor
screen may be adversely affe ...