Nissan Sentra manuals

Nissan Sentra Service Manual: System initialization

Description

If any of the following operations are performed, the initialization is necessary for normal operation of power window system.

CAUTION:

The following specified operations can not be performed under the non-initialized condition.

Work Procedure

1.STEP 1

  1. Turn ignition switch ON.
  2. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
  3. Operate the power window switch in the UP position (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 2 seconds or more.
  4. Release the switch and check that AUTO-UP function operates normally.

>> GO TO 2.

2.STEP 2

Check anti-pinch function. Refer to PWC-30, "Work Procedure".

>> END

Additional service when replacing power window main switch
Description When the power window main switch is replaced, the initialization is necessary for normal operation of power window system. CAUTION: The following specified operations can not be per ...

Anti-pinch inspection
Description If any of the following operations are performed, the initialization is necessary for normal operation of antipinch function. Disconnection and connection of battery cable from neg ...

Other materials:

Can communication circuit
Diagnosis procedure 1.Connector inspection Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Disconnect all the unit connectors on can communication system. Check terminals and connectors for damage, bend and loose connection. Is the inspection resu ...

The oil pressure warning lamp does not turn on
Description The oil pressure warning lamp stays off when the ignition switch is turned on. Diagnosis procedure 1.Check combination meter oil pressure warning light Select METER/M&A on CONSULT. Observe oil w/l data monitor while operating the ignition switch. Is the inspection r ...

A-bag branch line circuit
Diagnosis procedure Warning: Always observe the following items for preventing accidental activation. Before servicing, turn ignition switch off, disconnect battery negative terminal, and wait 3 minutes or more. (To discharge backup capacitor.) Never use unspecified tester or other ...

В© 2014-2026 Copyright b17.nisentra.com