Additional service when replacing control unit
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description
WARNING:
Always perform zero point reset using CONSULT when removing and installing the front passenger seat or servicing the occupant classification system. If zero point reset is not performed, the OCS may not operate normally, which may increase the risk of serious injury in a collision.
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement
WORK PROCEDURE WHEN REPLACING OCS CONTROL UNIT
1.PERFORM ZERO POINT RESET
Perform zero point reset. Refer to SRC-41, "ZERO POINT RESET : Special Repair Requirement".
>> Inspection End.
Zero point reset
Zero point reset : Description
Zero point reset is an initializing procedure for the OCS (weight) sensors that must be performed using CONSULT when removing and installing passenger seat or servicing the OCS system. If zero point reset is not performed, the initialization is incomplete and OCS may not operate normally.
NOTE:
Zero point reset : Special repair requirement
1.PERFORM ZERO POINT RESET
NOTE:
>> GO TO 2.
2.CONFIRM RESET
CAUTION:
Is zero point reset status ”complete”? YES >> Print out “ZERO POINT RESET CURRENT STATUS” screen. Inspection end.
NO >> Recheck the preliminary check items and perform zero point reset again.
Diagnosis and repair work flow
Intermittent incidentFront seat
Driver side
DRIVER SIDE : Exploded View
Driver side
Headrest
Headrest holder (locked)
Headrest holder (free)
Seatback silencer
Seatback trim
Seatback pad
Seat belt buckle
Seat cushion outer finisher (RH)
Slide cover (RH)
Seat cushion inner finisher (RH)
Recline mech ...
NISSAN Intelligent Key® (if so equipped)
WARNING
Radio waves could adversely affect
electric medical equipment. Those who
use a pacemaker should contact the
electric medical equipment manufacturer
for the possible influences before
use.
The Intelligent Key transmits radio
waves when the buttons are pr ...
C1601 Battery power supply
DTC Logic
DTC DETECTION LOGIC
DTC
Display item
Malfunction detected condition
Possible cause
C1601
BATTERY VOLT
When a power supply voltage to the EPS control unit
is maintained at 17.5 V or more or at less than 9 V
continuously for five second or more.
...