Diagnosis procedure
1.Check connector
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.Check harness for open circuit


Is the measurement value within the specification? Yes >> go to 3.
No >> repair the bcm branch line.
3.Check power supply and ground circuit
Check the power supply and the ground circuit of the bcm. Refer to the following.
Is the inspection result normal? YES (Present error)>>Replace the BCM. Refer to the following.
YES (Past error)>>Error was detected in the BCM branch line.
NO >> Repair the power supply and the ground circuit.
Hvac branch line circuit
Can communication circuitBcm branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the bcm for damage, bend and loose
connection (unit side and
connector side).
Is the inspection result normal?
Yes > ...
System initialization
Description
If any of the following operations are performed, the initialization is
necessary for normal operation of power
window system.
Disconnection and connection of battery cable from negative terminal.
When power window main switch replaced.
Electric power supply to power window m ...
Symptom diagnosis
Squeak and rattle trouble diagnoses
Work Flow
CUSTOMER INTERVIEW
Interview the customer if possible, to determine the conditions that exist
when the noise occurs. Use the Diagnostic
Worksheet during the interview to document the facts and conditions when the
noise occurs and any
custome ...