Nissan Sentra manuals

Nissan Sentra Service Manual: Bcm branch line circuit

Diagnosis procedure

1.Check connector

  1. Turn the ignition switch off.
  2. Disconnect the battery cable from the negative terminal.
  3. Check the terminals and connectors of the BCM for damage, bend and loose connection (unit side and connector side).

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair the terminal and connector.

2.Check harness for open circuit

  1. Disconnect the connector of bcm.
  2. Check the resistance between the bcm harness connector terminals.


Is the measurement value within the specification?


Is the measurement value within the specification? YES >> GO TO 3.

NO >> Repair the BCM branch line.

3.Check power supply and ground circuit

Check the power supply and the ground circuit of the BCM. Refer to the following.

Is the inspection result normal? Yes (present error)>>replace the bcm. Refer to the following.

Yes (past error)>>error was detected in the bcm branch line.

No >> repair the power supply and the ground circuit.

Strg branch line circuit
Diagnosis procedure 1.Check connector Turn the ignition switch off Disconnect the battery cable from the negative terminal. Check the terminals and connectors of the steering angle sensor for ...

Can communication circuit
Diagnosis procedure 1.Connector inspection Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Disconnect all the unit connectors on can communication syste ...

Other materials:

Component parts
Component parts location BCM (view with instrument panel removed) Key switch (without Intelligent Key) Push-button ignition switch (with Intelligent Key) IPDM E/R Illumination control switch Combination switch (lighting and turn signal switch) Front door lock LH (key cylin ...

Removal and installation
Av control unit Exploded view AV control unit Av control unit bracket (lh) AV control unit bracket (RH) Removal and installation Removal Caution: Remove battery terminal and av control unit after a lapse of 30 seconds or more after turning the ignition switch off. Before ...

Anti-pinch inspection
Description If any of the following operations are performed, the initialization is necessary for normal operation of antipinch function. Disconnection and connection of battery cable from negative terminal. When power window main switch replaced. Electric power supply to power window ma ...