Diagnosis Procedure

1.PERFORM INITIALIZATION PROCEDURE

Initialization procedure is executed and operation is confirmed.

Refer to PWC-29, "Work Procedure".

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 2.

2.CHECK ENCODER CIRCUIT

Check encoder circuit.

Refer to PWC-50, "DRIVER SIDE : Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.REPLACE POWER WINDOW MAIN SWITCH

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-39, "Intermittent Incident".

Rear rh side power window does not operate
When both power window main switch and rear power window switch RH are operated When both power window main switch and rear power window switch rh are operated : diagnosis procedure 1.CHECK REAR ...

Anti-pinch system does not operate normally (driver side)
Diagnosis Procedure 1.CHECK POWER WINDOW AUTO OPERATION Check AUTO operation when anti-pinch function does not operate. Refer to PWC-67, "Diagnosis Procedure". Is the inspection resu ...

Other materials:

Dtc/circuit diagnosis
Eco mode switch Component function check 1. Check eco mode switch operation Turn ignition switch ON. Check ECO mode indicator lamp turns ON/OFF on combination meter when turn ECO mode switch ON/ OFF. Is the inspection result normal? Yes >> inspection end No >> go to dm ...