Nissan Sentra manuals

Nissan Sentra Service Manual: SRS Air bag warning lamp does not turn OFF

Nissan Sentra Service Manual / Restraints / SRS airbag control system / Symptom diagnosis / SRS Air bag warning lamp does not turn OFF

Diagnosis Procedure

1.CHECK AIR BAG MODULE AND SEAT BELT PRE-TENSIONER

Check the deployment of air bag module.

Is air bag module deployed? YES >> Replace the malfunctioning parts.

NO >> GO TO 2.

2.CHECK AIR BAG FUSE

Check 10 A fuse [No.3, located in fuse block (J/B)].

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace the fuse.

3.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 4.

NO >> Replace harness connectors.

4.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 5.

NO >> Replace wiring harness.

5.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

  1. Replace air bag diagnosis sensor unit. Refer to SR-28, "Removal and Installation".
  2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 6.

6.REPLACE COMBINATION METER

  1. Replace combination meter. Refer to MWI-77, "Removal and Installation".
  2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 1.

Symptom diagnosis
...

SRS Air bag warning lamp does not turn ON
Diagnosis Procedure 1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT Check combination meter unit power supply and ground circuit. Refer to MWI-52, "COMBINATION METER : Diagnosis Pr ...

Other materials:

Supplemental air bag warning light
The supplemental air bag warning light, displaying in the instrument panel, monitors the circuits for the air bag systems, pretensioners and all related wiring. When the ignition switch is placed in the ON or START position, the supplemental air bag warning light illuminates for about ...

The oil pressure warning lamp does not turn on
Description The oil pressure warning lamp stays off when the ignition switch is turned on. Diagnosis procedure 1.Check combination meter oil pressure warning light Select METER/M&A on CONSULT. Observe oil w/l data monitor while operating the ignition switch. Is the inspection r ...

Battery current sensor
Exploded view Battery current sensor Current sensor harness connector Removal and installation Removal Loosen the battery terminal nut and disconnect battery negative terminal. Refer to PG-50, "Exploded View". Disconnect the harness connector from current sensor. ...